TP20 Probe Kit 2: (1) Std & (1) Med Force
Kit Includes:
1 - TP20 Probe Body
1 - Standard Force Module
1 - Medium Force Module
TP20
The TP20 probe body houses one half of the highly repeatable magnetic kinematic coupling that attaches the stylus module and body. The body also contains a magnetic proximity switch to inhibit triggering of the probe during automatic module changing with MCR20.
Note: If the probe is operated close to magnetized parts/ clamping etc, the probe trigger may become inhibited. Countermeasures include the use of long styli, stylus extensions or body orientation to increase the distance to the magnetic source. Alternatively, use the TP20 NI probe body.
TP20 Probe Modules
Module | Application | Trigger forces* | Stylus lengths | |
---|---|---|---|---|
SF- Standard force | Suited to the majority of applications | XY: 0.08 N Z: 0.75 N Stylus: 10 mm | 10 mm to 50 mm GF | |
MF- Medium force | Where a higher trigger force than standard is required | XY: 0.1 N Z: 1.9 N Stylus: 25 mm | 10 mm to 60 mm |